Material Safety Data Sheet for GP Cylindrical Alkaline Battery
Document Number: MAA100 Revision:29 Page
1
of
5
IDENTITY (As Used on Label and List)
Alkaline batteries
13A(LR20)/14A(LR14)/15A(LR6)/
24A
(LR03)
/25A
(
LR8D425)
/910A
(LR1)
Note: Blank spaces are not permitted if any item is not applicable or no
information is available, the space must be marked to indicate that.
-
Identification
Manufacturer's Name
GPI International Ltd.
Emergency Telephone Number
Address (Number, Street, City State, and
ZIP Code)
7/F, Building 16W, 16 Science Park West
Avenue
Telephone Number for information
852-2484-3111
Hong Kong Science Park, New Territories.
H.K.
Date of prepared and revision
01 Jan, 2022
Signature of Prepare (optional)
Section 2
Hazards Identification
Classification
N.A.
Section 3
Composition/Information
on
Ingredients
Ingredient
CAS# EINECS No. Approximate Content (wt%)
15A
(
LR6
)
24A
(
L
R03
)
14A
(
LR14
)
13A
(
L
R20
)
910A
(LR1)
25A
(LR8D425)
Manganese
Dioxid
e (MnO
2
)
1313-13-9
215-202-6 42.6 40.9 40.6 41.8 34.2 36.0
Zinc (Zn)
7440
-
66
-
6
231
-
175
-
3
1
6.1
1
4.8
1
6.0
1
7.4
13.5
17.
0
Water (H
2
O)
7732-18-5
231-791-2 12.2 11.7 11.0 11.1 9.5 6.5
Potassium
Hydrox
ide (KOH)
1310-58-3
215-181-3 5.2 4.8 7.0 7.0 4.2 1.3
Graphite
7782-42-5
231-955-3 3.0 1.7 3.2 3.4 3.0 2.3
B
rass
12597
-
71
-
6
603
-
111
-
8
2.4
3.0
1.2
0.8
2.3
3.5
Steel
7439-89-6
231-096-4 15.7 20.4 18.6 16.3 29.5 30.0
Ni
-
plating
7440
-
02
-
0
231
-
111
-
4
0.
3
0.3
0.
2
0.
2
0.3
0.6
Nylon
-
66
32131
-
17
-
2
608
-
706
-
6
1.6
1.5
1.6
1.4
2.9
2.2
Fiber
None
None
0.9
0.9
0.6
0.
6
0.6
0.6
Section 4
First Aid Measures
First Aid Procedures
If electrolyte leakage occurs and makes contact with skin, wash with plenty of water immediately.
If electrolyte comes into contact with eyes, wash with copious amounts of water for fifteen (15) minutes and
contact a
physician.
If electrolyte vapors are inh
aled, provide fresh air and seek medical attention if respiratory irritation develops. Ventilate the
contaminated area.

Probleemoplossing Klein Tools VDV501-770

Als je de handleiding al zorgvuldig hebt gelezen maar geen oplossing voor je probleem hebt gevonden, vraag dan andere gebruikers om hulp


Specificaties

Merk: Klein Tools
Categorie: Meetapparatuur
Model: VDV501-770

Vergelijkbare producten

Meetapparatuur - 25 Pagina's
Meetapparatuur - 48 Pagina's
Meetapparatuur - 36 Pagina's
Meetapparatuur - 4 Pagina's
Meetapparatuur - 48 Pagina's
Meetapparatuur - 8 Pagina's
Meetapparatuur - 32 Pagina's
Meetapparatuur - 28 Pagina's
Meetapparatuur - 20 Pagina's