Uni-T Multimeter UT890D+

Uni-T UT890D+ Handleiding

Hier is de Uni-T UT890D+ (Multimeter) gebruikershandleiding. 2 pagina's in taal Engels met een gewicht van 0.6 Mb. Als u geen antwoorden op uw probleem kunt vinden Vraag het onze community.

Pagina 1/2
Buzzer
Fuse
Auto shut off
Grounding
AC
Double Insulation
Relative Measurement
Warning
DC
Diode
Range
600mV 0.1mV
0.001V
0.01V
0.1V
1V
6V
60V
600V
1000V
Resolution Accuracy
±(0.5%+4)
±(0.5%+2)
±(0.7%+10)
Range
600 0.1Ω Ω
0.001k
0.01k
0.1k
0.001M
0.01M
6k
60k
600k
6M
60M
Resolution Accuracy
±(0.8%+5)
±(0.8%+3)
±(1.0%+25)
Operating Manual
I. General Introduction
This brand new UT890C+/D Operating Manual is a handheld
3-5/6 digit True RMS Digital Multi-meter featuring stable performance
and high reliability. Its whole circuit design utilizes a large scale
integrated circuit that uses ADC converter as its core and is
further equipped with full function overload protection, making it an
ideal tool for users to measure the followings: DC and AC voltage,
electric current, resistance, capacitance, frequency, temperature
(UT890D/C+), diode, triode and continuity test.
Safety Rules and Instructions
This unit is designed and produced in strict accordance with
GB4793, Safety Requirements for Electronic Measuring Instrument
and Safety Standards coded as IEC61010-1 and IEC1010-2-032. It
complies with safe standards, such as double insulation, over voltage
(CAT II 1000V, CAT III 600V) and class of pollution II. Please follow
the instructions contained in this manual, otherwise the protection
provided by this unit may be impaired.
You should not use this unit unless its back cover is properly
secured in place, otherwise you are exposed to shock hazard.
The range switch should be switched to a correct range.
Check the insulation layer of the test leads to ensure no
damaged or broken cable.
The red and black test leads should be well inserted into the
jacks that are in compliance with the measurement requirements to
ensure good contact.
The input signal should not exceed the specified limit value
to avoid shock or unit damage.
It is prohibited to change range when measuring voltage or
electric current so as to avoid unit damage.
Damaged fuse must only be replaced with fuse with identical
specification.
To avoid electric shock, the potential difference measured
between “COM” and earth “ ” should be no more than 1000V.
To avoid electric shock, test with great caution in case the
voltage to be measured maybe higher than DV 60V or AC 30Vrms.
Battery should be replaced in time so as to ensure measurement
accuracy when the LCD displays “ ”.
Power should be turned off immediately upon the test is completed
and battery should be taken out if it may not be used for a long
period of time.
Do not use the unit under an environment with high temperature
and high humidity, especially not store it in a wet place as the
dampened unit may perform badly.
Please do not change the circuit of the unit arbitrarily so as to
avoid unit damage or safety hazard.
Maintenance: Please use wet cloth and mild detergent rather
than abrasive material or solvent for the cleaning of its exterior housing.
III. Characteristics
More than 30 functional ranges are available.
LCD display, visible area 63×29mm.
Over range display “OL”.
Maximum displayed value 5999.
Overload protection for all ranges.
Auto power off.
Temperature scope:
Working temperature: 0 ~40 32 ~104 ℃( ℉ ℉)
Storage temperature: -10 ~50 14 ~122 ℃( ℉ ℉)
Low battery indicator: The symbol “ ” will be displayed at top
left of the LCD.
It has functions, including data hold, measurement of maximum/
minimum value, relative measurement, backlight, etc.
II. Symbol Description
Low battery
IV. Technical Indexes
Accuracy: ± , 1 year warranty period( )α% reading plus figure
Environment Temperature: 23 ±5℃ ℃
Relative humidity: 75%
1. DC Voltage
Input impedance: 1GΩfor the range of 600mV while 10 for all
other ranges.
Overload protection: 750Vrms or at a peak value of 1000Vp-p.
2. AC Voltage
Range
6V 0.001V
0.01V
0.1V
1V
60V
600V
750V
Resolution Accuracy
±(0.8%+3)
±(1.0%+10)
Input impedance: 10MΩfor all the ranges.
Frequency scope: 40Hz – 1KHz (Only applicable to sine wave and
triangular wave, but only being referable for other waves whose
frequencies are equal or higher than 200Hz.)
Guaranteed Accuracy: within 5~100% of its range and allow less t
han 5 figures of remaining reading in case of short circuit.
Overload Protection: 750Vrms or at a peak value of 1000Vp-p.
Display: True RMS
3. DC Current
Range
6A 0.01μA
0.001mA
0.01mA
0.1mA
0.01A
6mA
60mA
600mA
20A
Resolution Accuracy
±(0.8%+8)
±(1.2%+5)
±(2.0%+5)
Overload prote.ction: Fuse F1-630mA/250V, F2-20A/250V
Maximum input current: 20A (measuring electric current between
5A and 20A, testing time ≤10 seconds, Interval≥15 mins).
Measuring voltage drop: 600mV when at its full range.
4. AC Current
Range
6mA 0.001mA
0.01mA
0.1mA
0.01A
60mA
600mA
20A
Resolution Accuracy
±(1.0%+12)
±(2.0%+3)
±(3.0%+5)
Overload protection: Fuse F1-630mA/250V, F2-20A/250V
Frequency scope: 40Hz – 1KHz (Only applicable to sine wave and
triangular wave, but only being referable for other waves whose
frequencies are equal or higher than 200Hz.)
Guaranteed Accuracy: within 5~100% of its range and allow less
than 2 figures of remaining reading in case of short circuit.
Maximum input current: 20A (measuring electric current between
5A and 20A, testing time ≤10 seconds, Interval≥15 mins) Measuring
voltage drop: 600mV when at its full range
Display: True RMS
5. Resistance
Range of 600Ω: measured value=displayed value - value shown when
test leads are short connected Open circuit voltage: About 1V
Overload protection: 600Vrms.
6. Capacitance
Range
9.999n 0.001nFF
0.01nF0.1μF
1 Fμ
10μF
99.99nF~ 999.9μF
9.999mF
99.99mF
Resolution Accuracy
±(5.0%+35)
±(2.5%+20)
±(5.0%+10)
10mFC20mF:±(10.0%+5)
>20mF:reading is for reference only
Range: Auto (Reading for distributed capacitance of test leads may
be shown when the unit is in open circuit. It is recommended to use
REL mode to measure for any capacitance of less than 1μF)
Overload protection: 600Vrms.
7. Frequency
Range
9.999Hz~10.00MHz 0.001Hz~0.01MHz
Resolution Accuracy
±(0.1%+5)
Range: Auto
Input frequency:
≤100KHz: 100mVrms≤Input frequency≤30Vrms;
100kHz~1MHz: 200mVrms≤Input frequency≤30Vrms;
1MHz: 600mVrms≤Input frequency≤30Vrms;
Overload protection: 600Vrms .
8.Diode & Buzzer Continuity Test
Range Description
Display forward voltage of the diode under test (approximate
value) and the range scope is 0 V. ~3
If it is equal or less than 10 , the buzzer beeps, indicatingΩ
circuit is closed; if it is equal or more than 100 ,the buzzer Ω
remain silence, indicating open circuit with a voltage of
approximately 1V.
Overload protection: 600Vrms .
9. hFE Test for Transistors
Range Description
hFE
Test Condition
It can be used to test hFE specificiations
for Transistors of NPN or PNP type.
Display range: 0-1000β
Base current is about
10μA, Vce is about
1.2V
10. Temperature Test (Only for UT890C+)
Accuracy
±3
±5
±(1.0%+3)
±(1.5%+5)
±(2.5%+5)
±(2.0%+3)
Function Range Resolution
Temperature
Temperature
-400
1>0100
>100 0~100
-40~32OF
1OF
>32~212
OF
>212~1832OF
V. How to Use it:
Instructions before operating
(1). Once the unit is powered up, please check the 9V battery
contained in this unit, and if the battery
voltage is insufficient, there will be a
symbol “ ” being displayed on the
screen, then the battery should be
replaced to ensure measurement
accuracy.
(2). The symbol “ ” located beside
the jacks for test leads warns that for
the prevention of internal circuit from
being damaged, the input voltage or
current should not exceed the rated
value.
(3). Before measuring, the range switch should be switched into the
range needed.
(4). Instrument Introduction (see Fig. 1):
1
2
3
4
5
6
(see Fig. 1)
Combination keys: HOLD/ /SELECT(UT890C+)
LCD
Combination keys: MAX MIN/
Range switch
Jack for transistor testing
Input Jack
1. DC Voltage Measurement
(1). Insert the black test lead into “COM”, while insert the red test
lead into “V”.
(2). Switch the range switch into the range ”. Then connect
the test leads in parallel with the power or load under test, the polarity
shown by the unit is the polarity of the terminal connected by the
red test lead.
Notes
1) If the voltage being measured remains unknown, turn the range
switch into the maximum range first and then gradually adjusting it
downward.
2) If “OL” is shown on the LCD, it indicates that it has exceeded the
range, so the range should be switched into a higher one.
3) The symbol “ ” besides the “V” jack indicates that no voltage
higher than 1000V should be input into the unit, as though it is
possible to display a higher voltage, but this may incur a risk of
damaging internal wiring!
4) In case the input impedance is around 10MΩ, it may result in
measurement error if such load is connected into a circuit with high
impedance. Under most circumstances, if the circuit impedance is
less than 10kΩ, then the error is ignored (0.1% or even lower).
5) Especially be cautious to avoid shock when measuring high voltage.
2. AC Voltage Measurement
(1) Insert the black test lead into “COM”, while insert the red test
lead into “V”.

Probleemoplossing Uni-T UT890D+

Als je de handleiding al zorgvuldig hebt gelezen maar geen oplossing voor je probleem hebt gevonden, vraag dan andere gebruikers om hulp


Specificaties

Merk: Uni-T
Categorie: Multimeter
Model: UT890D+

Vergelijkbare producten

Multimeter - 1 Pagina's
Multimeter - 1 Pagina's
Multimeter - 2 Pagina's
Multimeter - 1 Pagina's
Multimeter - 1 Pagina's
Multimeter - 20 Pagina's
Multimeter - 2 Pagina's
Multimeter - 2 Pagina's
Multimeter - 2 Pagina's
Multimeter - 25 Pagina's
Multimeter - 1 Pagina's
Multimeter - 2 Pagina's